{"product_id":"63a-lcd-reclosing-protector-2p-l-n-disc","title":"63A LCD Reclosing Protector 2p L+N Disc","description":"\u003ch4 dir=\"ltr\"\u003eTotal Grid Protection for Every Pakistani Home — 63A LCD Reclosing Protector \u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003ePakistan's electricity grid presents a specific combination of threats that most homeowners dramatically underestimate. Load shedding recovery spikes. Evening voltage drops during peak summer demand in Lahore, Karachi, and Islamabad. Lightning-induced surges during monsoon season. Floating neutral faults in older residential wiring. Grid switching transients from industrial areas feeding residential neighborhoods. These are not rare events — they are regular, recurring features of electricity supply across Pakistan, and every one of them poses a genuine threat to the expensive appliances your household depends on daily.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eModern Pakistani homes are increasingly equipped with inverter air conditioners, smart refrigerators, LED televisions, home automation hubs, and other electronics whose microprocessor-controlled circuits are extraordinarily sensitive to voltage instability. A standard mechanical circuit breaker protects your wiring from sustained overload — but it does nothing to protect your appliances from the brief, violent voltage events that destroy electronics in milliseconds. And when a standard breaker trips, it stays off until someone physically returns to the distribution board to reset it.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e addresses both limitations simultaneously. It monitors incoming Live and Neutral line voltage and current continuously, cuts power in microseconds when unsafe conditions are detected, displays the exact fault condition on a built-in LCD screen, and automatically restores power once grid conditions return to safe parameters — without any manual intervention required.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThis is the electrical safety device that Pakistan's grid conditions demand, and distribution board lineup has been missing until now. Explore our full\u003ca href=\"https:\/\/smartswitch.pk\/collections\/home-automation\"\u003e smart home collection at Smart Switch\u003c\/a\u003e\u003ca href=\"https:\/\/nexcomfort.com\"\u003e \u003c\/a\u003eto see how the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e completes a comprehensive electrical safety and automation setup.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eHow Pakistan's Grid Destroys Appliances — And What the 63A LCD Reclosing Protector Does About It\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eUnderstanding why the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e is necessary requires understanding the two distinct electrical threats that Pakistani homeowners face — both of which standard circuit breakers are powerless to address:\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eThreat 1: Over-Voltage Spikes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eWhen load shedding ends and grid power is restored across a neighborhood simultaneously, the sudden reconnection of thousands of homes creates a brief but violent voltage spike on the supply line. Similar spikes occur during lightning strikes within the distribution network, grid switching events from nearby industrial consumers, and fault clearing on high-voltage transmission lines.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThese over-voltage events — lasting fractions of a second — are sufficient to destroy the motherboards of smart televisions, damage the inverter circuits of modern air conditioners, burn out the control boards of expensive refrigerators, and fry the power supplies of computers and home automation hubs. A mechanical circuit breaker cannot respond quickly enough to protect against these events. The \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e detects the over-voltage condition and trips the relay in microseconds — before the dangerous voltage reaches your appliances.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eThreat 2: Under-Voltage Sags\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eLess dramatic than spikes but often more damaging over time, voltage sags occur across Pakistani residential areas during peak demand periods — typically summer afternoons and evenings when widespread air conditioner usage loads distribution transformers beyond their rated capacity. Grid voltage can drop from the nominal 220V to 180V, 160V, or lower in severely affected areas.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eWhen line voltage drops significantly below the nominal value, resistive and motor loads draw higher current to maintain power output — a compensation mechanism that creates excessive heat inside motor windings, compressor coils, and transformer cores. Over time, this thermal stress degrades insulation, accelerates winding failure, and dramatically shortens the operational lifespan of inverter ACs, refrigerator compressors, and washing machine motors.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eAccording to the \u003ca href=\"https:\/\/www.iec.ch\/homepage\"\u003eInternational Electrotechnical Commission (IEC)\u003c\/a\u003e, sustained operation below rated voltage is one of the primary causes of premature motor and compressor failure in residential electrical equipment — a particularly serious issue in Pakistan where voltage sags are frequent and prolonged during summer months.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e cuts power to protected circuits the moment voltage drops below your configured minimum threshold — protecting compressor motors from the thermal damage that builds invisibly over months of under-voltage operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eReal-Time LCD Display — See Your Grid's Health at a Glance\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eMost traditional surge protectors and voltage guards operate silently behind opaque panels — you only know they have tripped when an appliance stops working. Diagnosing whether the cause was a blown fuse, a tripped main breaker, a neighborhood outage, or a voltage fault requires checking multiple points in your distribution board, often without any useful information about what actually happened.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e eliminates this diagnostic uncertainty with a \u003cstrong\u003ebuilt-in backlit LCD digital display\u003c\/strong\u003e that shows live electrical data continuously:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time line voltage (V)\u003c\/strong\u003e — see exactly what voltage your grid is delivering at this moment — whether it is a healthy 220V, a concerning 180V sag, or a dangerous 260V spike after load shedding restoration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time current draw (A)\u003c\/strong\u003e — monitor how many amps your protected circuit is currently consuming\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault condition indication\u003c\/strong\u003e — when the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e trips, the screen displays the specific fault type — over-voltage, under-voltage, or over-current — so you know exactly what caused the disconnection without any guesswork\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecovery status\u003c\/strong\u003e — monitor the countdown to automatic reclosing after a fault, giving you visibility into when power will be restored\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eThis LCD display transforms your distribution board from a black box into a visible, readable electrical monitoring station — accessible to any homeowner without electrical training or external test equipment\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eAutomatic Reclosing — Power Restores Itself When the Grid Recovers\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eThe feature that most decisively separates the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e from conventional surge protectors and standard circuit breakers is its \u003cstrong\u003eintelligent automatic reclosing function\u003c\/strong\u003e — the ability to restore power automatically once grid conditions return to safe parameters.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eThe problem with standard breakers:\u003c\/strong\u003e\u003cbr\u003eA conventional mechanical circuit breaker or basic surge protector trips when a fault occurs and stays off permanently until someone physically walks to the distribution board and resets it. If a voltage fault occurs while you are at work, traveling, or asleep — your refrigerator goes off, food spoils, security cameras lose power, and your smart home devices go offline until someone manually resets the device.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow the 63A LCD Reclosing Protector works differently:\u003c\/strong\u003e\u003cbr\u003eWhen an electrical fault triggers the internal relay, the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e disconnects the protected circuit immediately — protecting your appliances from the dangerous condition. It then enters a monitoring phase, continuously checking the incoming grid voltage and current. Once the grid returns to safe parameters and remains stable for the configured recovery delay period, the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e automatically re-engages the relay and restores power — completely without manual intervention.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eThe recovery delay timer is critically important for air conditioners:\u003c\/strong\u003e\u003cbr\u003eInverter air conditioner compressors require a pressure equalization period of 30 to 180 seconds after a power interruption before they can safely restart. Restoring power too quickly causes the compressor to restart against high back-pressure, stressing the motor and potentially causing immediate damage. The \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e's adjustable recovery delay timer can be set to the appropriate waiting period for your specific AC model — ensuring power is only restored after the compressor has had adequate time to equalize, preventing restart damage that a simple automatic switch-back would cause.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eAccording to \u003ca href=\"https:\/\/www.wapda.gov.pk\"\u003eWAPDA's official electrical guidance\u003c\/a\u003e, compressor protection and appropriate restart delays are among the most important considerations for protecting AC and refrigeration equipment during power restoration after outages — and the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e's adjustable delay timer addresses this requirement directly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eComplete 2P Live + Neutral Isolation — Safety That Single-Pole Cannot Match\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eMost budget voltage protectors available in Pakistan's market use a \u003cstrong\u003esingle-pole design\u003c\/strong\u003e — they disconnect only the Live wire when a fault is detected, leaving the Neutral wire continuously connected to your home appliances. In standard, properly functioning wiring, this is adequate. But Pakistani electrical installations — particularly in older homes and apartments — frequently have floating neutral conditions, reversed polarity connections, and ground fault scenarios where a connected Neutral wire can still transmit dangerous voltages to appliance chassis and metal surfaces.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eThe \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e uses a \u003cstrong\u003ecomplete dual-pole (2P) disconnect mechanism\u003c\/strong\u003e — both the Live and Neutral lines are physically broken simultaneously the moment a fault triggers the relay. This provides:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal electrical isolation\u003c\/strong\u003e — no voltage path of any kind exists between the grid and your protected appliances during a fault condition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloating neutral protection\u003c\/strong\u003e — eliminates the shock hazard from Neutral-carried voltages in installations with neutral earthing problems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround fault safety\u003c\/strong\u003e — prevents back-feed currents from reaching appliance chassis through a connected Neutral during complex fault scenarios\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete appliance safety\u003c\/strong\u003e — anyone servicing appliances or touching metal enclosures during a protection event faces no voltage risk from either conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003eThis 2P isolation standard is the same approach used in professional-grade industrial protection equipment — and the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e brings it to Pakistani residential and commercial distribution boards at an accessible price point. For technical reference on the safety importance of dual-pole isolation in residential applications, see \u003ca href=\"https:\/\/www.iec.ch\/homepage\"\u003eIEC 60364 electrical installation standards\u003c\/a\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eFully Adjustable Protection Parameters — Tuned to Your Home\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eEvery Pakistani home has a different electrical load profile, different appliance sensitivity requirements, and different local grid characteristics. The \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e avoids the limitations of fixed, hardcoded protection thresholds by providing full parameter customization through front-panel buttons:\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOver-voltage cutoff threshold:\u003c\/strong\u003e\u003cbr\u003eSet the maximum voltage level above which the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e disconnects the circuit. Homes in areas prone to severe post-load-shedding spikes may configure a tighter upper limit to protect sensitive electronics; homes with more stable supply can set a wider tolerance.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eUnder-voltage cutoff threshold:\u003c\/strong\u003e\u003cbr\u003eConfigure the minimum voltage below which the protector disconnects. Homes with inverter ACs and refrigerators — most sensitive to low-voltage damage — can set a higher minimum threshold; installations with primarily resistive loads can accept lower voltages without disconnection.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOver-current protection limit:\u003c\/strong\u003e\u003cbr\u003eAdjust the maximum current threshold up to 63A. This allows the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e to function as an over-current protection device for specific sub-circuits, cutting power if current draw exceeds your configured limit — protecting against sustained overloads that a standard breaker may not trip on immediately.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eRecovery delay timer:\u003c\/strong\u003e\u003cbr\u003eSet a custom delay in seconds between when grid voltage stabilizes and when the \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e automatically recloses — from 30 seconds for non-compressor loads to 180 seconds or more for inverter AC compressor protection. This parameter alone prevents the compressor restart damage that makes the difference between a protected AC and a damaged one.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eDIN Rail Installation — Fits Directly Into Your Existing Panel\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eThe \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e is designed for direct installation into your existing residential or commercial distribution board — no panel replacement, no rewiring, no specialist installation required beyond a certified electrician connecting the incoming and outgoing terminals.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eIts compact form factor snaps directly onto a standard \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e — the universal mounting standard used in Pakistani residential consumer units and commercial distribution boards. For reference on DIN rail mounting standards and compatibility, see \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/DIN_rail\"\u003eWikipedia's DIN rail technical overview\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eWith a \u003cstrong\u003e63A continuous current rating\u003c\/strong\u003e, this protector is sized for:\u003c\/p\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhole-home sub-panels\u003c\/strong\u003e — protecting all circuits downstream of a sub-distribution board\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated appliance circuits\u003c\/strong\u003e — individual protection for high-value inverter ACs, refrigerators, or home automation systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial kitchen and workshop circuits\u003c\/strong\u003e — heavy-load protection for high-draw commercial equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRental property distribution boards\u003c\/strong\u003e — automatic protection and reclosing that requires no on-site management after tenant-caused trips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e63A 2P L+N LCD Reclosing Protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003eUp to 63A Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P (Live + Neutral Simultaneous Disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003eAC 220V \/ 230V Nominal (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eReal-Time LCD (Voltage \u0026amp; Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Reclosing\u003c\/td\u003e\n\u003ctd\u003eYes — Automated After Grid Stabilization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eAdjustable Cutoff Threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnder-Voltage Protection\u003c\/td\u003e\n\u003ctd\u003eAdjustable Cutoff Threshold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-Current Protection\u003c\/td\u003e\n\u003ctd\u003eAdjustable up to 63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecovery Delay\u003c\/td\u003e\n\u003ctd\u003eUser-Adjustable (Seconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eWho Needs the 63A LCD Reclosing Protector in Pakistan?\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePakistani homeowners with inverter ACs and smart appliances\u003c\/strong\u003e — Protect the microprocessor-controlled circuits of inverter air conditioners, smart refrigerators, LED TVs, and home automation hubs from Pakistan's grid voltage instability\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHomeowners in load-shedding-affected areas\u003c\/strong\u003e — Automatic reclosing means your refrigerator, security cameras, and smart home devices restore themselves after every load-shedding cycle without a single trip to the distribution board\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOwners of expensive electronics and home appliances\u003c\/strong\u003e — One \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e protecting a sub-panel pays for itself by preventing a single inverter AC or refrigerator compressor failure\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCommercial and rental property managers\u003c\/strong\u003e — Set and forget automatic protection and reclosing that requires no on-site management after fault events\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSolar system owners\u003c\/strong\u003e — Protect inverter output circuits from grid-side voltage events and monitor supply quality in real time through the LCD display\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4 dir=\"ltr\"\u003eThe Smart Switch Promise\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003eAt Smart Switch, every product we feature is chosen because it solves a real problem that Pakistani homeowners genuinely face. The \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e earns its place in our electrical safety lineup by delivering the voltage monitoring, fault protection, automatic recovery, and 2P isolation that Pakistan's grid conditions make genuinely necessary — not just theoretically useful.\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003eYour appliances are expensive. Your grid is unpredictable. The \u003cstrong\u003e63A LCD Reclosing Protector\u003c\/strong\u003e sits between the two — permanently, automatically, and without requiring any ongoing attention.\u003cimg class=\"aligncenter size-full wp-image-9441\" src=\"https:\/\/nexcomfort.com\/wp-content\/uploads\/2026\/09\/WhatsApp-Image-2026-09-02-at-6.58.53-PM-1.jpeg\" alt=\"\" width=\"1024\" height=\"1024\"\u003e \u003cimg class=\"aligncenter size-large wp-image-9442\" src=\"https:\/\/nexcomfort.com\/wp-content\/uploads\/2026\/09\/WhatsApp-Image-2026-09-02-at-6.58.53-PM.jpeg\" alt=\"63A LCD Reclosing Protector\" width=\"1024\" height=\"1024\"\u003e \u003cimg class=\"aligncenter size-large wp-image-9443\" src=\"https:\/\/nexcomfort.com\/wp-content\/uploads\/2026\/09\/WhatsApp-Image-2026-09-02-at-6.58.52-PM-1-1024x512.jpeg\" alt=\"63A LCD Reclosing Protector\" width=\"1024\" height=\"512\"\u003e \u003cimg class=\"aligncenter size-large wp-image-9444\" src=\"https:\/\/nexcomfort.com\/wp-content\/uploads\/2026\/09\/WhatsApp-Image-2026-09-02-at-6.58.52-PM.jpeg\" alt=\"63A LCD Reclosing Protector\" width=\"1024\" height=\"1024\"\u003e\u003c\/p\u003e","brand":"SmartSwitch.Pk","offers":[{"title":"Default Title","offer_id":50528659472547,"sku":"N63ALRP","price":6400.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0776\/6651\/7155\/files\/63ALCDReclosingProtector_1.png?v=1790329545","url":"https:\/\/smartswitch.pk\/products\/63a-lcd-reclosing-protector-2p-l-n-disc","provider":"SmartSwitch.Pk","version":"1.0","type":"link"}